Reference Guide

Recommended
Response
Action
Storage objects are unavailable in the current system configuration. Make sure that
the storage devices are installed in the system, and then retry the operation after
the Collect System Inventory On Restart (CSIOR) feature has updated the system
inventory. If the issue persists, contact your service provider.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR0702
Message The value entered for the arg1 option is invalid
Arguments arg1 = option name
Detailed
Description
The value entered for the option name identified in the message is invalid.
Recommended
Response
Action
For more information, run the RACADM command "racadm raid help createvd".
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
STOR071
Message The Span Count is not valid for creating a RAID 10. Valid Span counts are arg1 .
Arguments arg1 = valid span counts
Detailed
Description
The configuration operation could not be performed because the specified span
count is not valid.
Recommended
Response
Action
Enter a valid span count, and then retry the operation.
Category Configuration (STOR = Storage)
1684