Reference Guide
Severity Severity 3 (Informational)
No alerts are applicable for this message
STOR063
Message Unable to assign the specified virtual disk to multiple Virtual Adapters in single
assignment mode.
Detailed
Description
In order to prevent data loss, the system has prevented the assignment of a Virtual
Disk to multiple Virtual Adapters because the clustered assignment mode is not
enabled.
Recommended
Response
Action
Enable clustered assignment mode or unassign the virtual disk from the Virtual
Adapter it is currently assigned to and retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR064
Message One or more physical disks specified for creating a virtual disk do not have the
same block size.
Detailed
Description
Unable to create the requested virtual disk because the physical disks specified did
not have the same block size.
Recommended
Response
Action
Verify that the physical disks selected for creating the virtual disk have the same
block size and retry the operation. The block size can be determined by reviewing
the physical disk inventory and checking the BlockSize property for each physical
disk.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR065
Message One or more physical disks specified for creating a virtual disk are not T10
Protection Information capable.
Detailed
Description
Unable to create the requested virtual disk because one or more specified physical
disk(s) is not T10 Protection Information capable.
Recommended
Response
Action
Verify that the physical disks selected for creating a virtual disk are T10 Protection
Information capable, and then retry the operation.