Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
STOR052
Message Unable to create virtual disk, maximum number of created virtual disks per
controller or diskgroup has been reached.
Detailed
Description
Virtual disks cannot be created because the maximum number of logical drives per
controller or diskgroup is reached.
Recommended
Response
Action
Refer to the Users Guide of the specific controller available at the support site for
information on the number of supported virtual disks allowed.
Category Configuration (STOR = Storage)
Severity Severity 3 (Informational)
No alerts are applicable for this message
STOR053
Message The controller key is not present. The key must be retrieved from the Dell Key
Management Server.
Detailed
Description
The system could not obtain a controller key from the Dell Key Management
Server.
Recommended
Response
Action
For more information about obtaining a key, see Dell Key Manager or Lifecycle
Controller Remote Services Guide availalbe at dell.com/support/manuals.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR054
Message Controller is not CacheCade capable.
Detailed
Description
The controller or the firmware on the controller does not support the CacheCade
feature.
Recommended
Response
Action
Refer to the specific controller users guide for more information.
Category Configuration (STOR = Storage)