Reference Guide
Arguments arg1 = device name
Detailed
Description
The device identified in the message that was previously in an error state has
returned to a normal state. For example, if an enclosure became too hot and
subsequently cooled down, or if a degraded virtual disk returns to normal state.
Recommended
Response
Action
No response action is required.
Category Storage (STOR = Storage)
Severity Severity 3 (Informational)
OMSA Event ID 2121
OMSA Trap ID 75200;80200;85200;90200;95200;100200;105200;110200;115200;120100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
STOR0212
Message The arg1 has failed.
Arguments arg1 = device name
Detailed
Description
The device (physical disk or an enclosure) identified in the message has failed. The
device (physical disk or an enclosure) failure was detected while performing a
rescan. However, physical disk failures are also detected during a check
consistency operation.
Recommended
Response
Action
Replace the identified device. A failed device is inidicated with a red color "X" status
icon. Perform a rescan after replacing the failed device.
Category Storage (STOR = Storage)
Severity Severity 1 (Critical)
OMSA Event ID 2048
OMSA Trap ID 75400;80400;85400;90400;95400;100400;105400;110400;115400;120400
1659