Reference Guide

Severity Severity 1 (Critical)
Trap/EventID 2385
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SEC0041
Message BIOS is unable to configure the Intel Trusted Execution Technology (TXT).
Detailed
Description
TXT initialization cannot be completed because system configuration may have
changed.
Recommended
Response
Action
Check system hardware inventory for TPM presence, clear and reconfigure TPM
and TXT in BIOS setup menu.
Category System Health (SEC = Security Event)
Severity Severity 1 (Critical)
Trap/EventID 2385
LCD Message Unable to configure TXT. Reconfigure TPM and TXT in BIOS.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SEC0042
Message Processor detected a problem while performing an Intel Trusted Execution
Technology (TXT) operation.