Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
RED046
Message A recurring operation of type arg1 was unable to create a job because the task type
is now disabled.
Arguments arg1 = operation type
Detailed
Description
The operation identified in the message was disabled and the iDRAC was unable to
create the next job in the sequence.
Recommended
Response
Action
Enable the operation identified in the message and retry the operation. To enable
the Automatic Server Profile Backup operation, run the following racadm
command: "racadm set lifecycleController.lcattributes.AutoBackup 1". To enable
the Automatic Update operation, run the following racadm command: "racadm set
lifecycleController.lcattributes.AutoUpdate 1".
Category Updates (RED = FW Download)
Severity Severity 3 (Informational)
LCD Message <task type> A recurring task was unable to create a job because the task type is
now disabled.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
RED047
Message A recurring operation arg1 was not created because the operation is already
configured.
Arguments arg1 = operation type
Detailed
Description
An Automatic Server Profile Backup or Automatic Update operation is already
configured.
1535