Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
RDU8516
Message CMC arg1 : failover initiated by RACADM interface.
Arguments arg1 = slot number
Detailed
Description
A failover has been requested from the RACADM command line interface.
Recommended
Response
Action
No response action is required.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
RDU8517
Message CMC arg1 : no action allowed while firmware update is in progress
Arguments arg1 = slot number
Detailed
Description
No failover or other action can occur while a CMC firmware update is in progress.
Recommended
Response
Action
No response action is required. Wait until the firmware update is complete and
retry the operation.