Reference Guide

Recommended
Response
Action
Check the status of the standby CMC and make sure the firmware version matches
the primary CMC. Then reseat the CMC and retry the operation. If the issue
persists, contact your service provider.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
RDU8511
Message Unable to failover, CMC arg1 in unknown state.
Arguments arg1 = slot number
Detailed
Description
For failover, the standby CMC needs to be present, at the same firmware version as
the primary CMC and healthy. During failover, the active CMC resets and the
standby CMC becomes active. This message is logged when the standby CMC
does not meet this criteria
Recommended
Response
Action
Check the status of the standby CMC and make sure the firmware version matches
the primary CMC. Then reseat the CMC and retry the operation. If the issue
persists, contact your service provider.
Category Audit (RDU = Redundancy)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
1500