Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
RDU0031
Message The arg1 voltage redundancy is lost.
Arguments arg1 = name
Detailed
Description
The system has redundant voltage lines. One of voltage line is no longer available.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) If the issue still persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health (RDU = Redundancy)
Severity Severity 1 (Critical)
Trap/EventID 2473
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC ✔* ✔*
RDU0032
Message The arg1 voltage redundancy is degraded.
Arguments arg1 = name
Detailed
Description
The system has multiple redundant voltage lines. One or more of these voltage
lines is no longer available.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) If the issue still persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health (RDU = Redundancy)
Severity Severity 2 (Warning)
Trap/EventID 2474
1494