Reference Guide

Detailed
Description
The current power supply configuration does not meet the platform requirements
to enable redundancy. If a power supply fails the system may shut down.
Recommended
Response
Action
If unintended, review system configuration and power consumption and install
power supplies accordingly. Check power supply status for failures.
Category System Health (RDU = Redundancy)
Severity Severity 3 (Informational)
Trap/EventID 2475
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
RDU0015
Message The power supplies are not redundant. Insufficient resources to maintain normal
operations.
Detailed
Description
The system may power down or operate in a performance degraded state.
Recommended
Response
Action
Check the event log for power supply failures. Review system configuration and
power consumption and upgrade or install power supplies accordingly.
Category System Health (RDU = Redundancy)
Severity Severity 1 (Critical)
Trap/EventID 2473
LCD Message PSUs are not redundant. Insufficient resources. Check PSU cables.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
1488