Reference Guide
RDU0011
Message The power supplies are redundant.
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (RDU = Redundancy)
Severity Severity 3 (Informational)
Trap/EventID 2475
OMSA Event ID 5304
OMSA Trap ID 5304
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔*
RDU0012
Message Power supply redundancy is lost.
Detailed
Description
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended
Response
Action
Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health (RDU = Redundancy)
Severity Severity 1 (Critical)
Trap/EventID 2473
LCD Message Lost PSU redundancy. Check PSU cables
OMSA Event ID 5306
1486