Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC985
Message Unable to configure the cfgServerBootOnce object.
Detailed
Description
The object "cfgServerBootOnce" cannot be configured if the object
"cfgServerFirstBootDevice" is set to F10, F11, or BIOS value.
Recommended
Response
Action
Change the value of the object "cfgServerFirstBootDevice" using the RACADM
command "racadm config -g cfgServerInfo -o cfgServerFirstBootDevice<value
other than F10, F11, and BIOS>", and retry configuring the object
"cfgServerBootOnce".
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC986
Message The "vmkey" sub-command is deprecated.
Detailed
Description
The "vmkey" sub-command is deprecated, and the functionality is available using
"vflashsd" sub-command.
Recommended
Response
Action
Use "vflashsd" sub-command instead of "vmkey". For more information about the
sub-command, use "racadm help vflashsd" command.
Category Configuration (RAC = RAC Event)
1474