Reference Guide

Detailed
Description
Another import operation cannot be started if an import operation that was
performed earlier has some pending or commited configuration changes.
Recommended
Response
Action
Wait until the configuration changes are applied before starting another import
operation. Use the racadm jobqueue view command to check the status of the
current import operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC962
Message Unable to continue with the operation because Lifecycle Controller is in recovery
state,
Detailed
Description
Lifecycle Controller must be enabled to run the operation.
Recommended
Response
Action
Enable the Lifecycle controller using the racadm set
LifeCycleController.LCAttributes.LifecycleControllerState 1 command, and retry the
operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
1462