Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC946
Message Unable to set the NIC to Auto Dedicated NIC mode.
Detailed
Description
The "Auto Dedicated NIC" mode cannot be set for a NIC if the NIC selection mode
is set to "Dedicated NIC".
Recommended
Response
Action
To set the NIC to Auto Dedicated NIC mode, set NIC selection mode to "Shared
NIC", and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC947
Message Invalid object value specified.
Detailed
Description
The value used for the object set operation is invalid.
Recommended
Response
Action
Make sure to specify the value depending on the type of object. For more
information, see RACADM help.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔
CMC
1454