Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1182
Message Unable to retrieve information for the Power group or attribute because the server
is not PMBus capable.
Detailed
Description
The server instrumentation can not provide any information related to power
because PMBus capability is not present or the PSU(s) with PMBus capability have
been removed.
Recommended
Response
Action
No response action is required.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1183
Message Unable to assign IP addresses 169.254.0.3 and 169.254.0.4 to the device OSBMC
USBNIC because the IP addresses entered are reserved for the iDRAC Direct
feature.
Detailed
Description
The IP addresses 169.254.0.3 and 169.254.0.4 cannot be assigned to the device
identified in the message because the IP addresses entered are reserved for the
iDRAC Direct feature.
Recommended
Response
Action
Enter another appropriate IP address, and then retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
1438