Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1133
Message BIOSRTDRequested value is modified successfully.The BIOS reset to default values
operation is pending a server restart.
Detailed
Description
The BIOSRTDRequested attribute was modified successfully.The BIOS reset to
default values operation is pending a server restart.
Recommended
Response
Action
To apply the BIOS default values, restart the server. After the server has restarted,
the default BIOS values will be accessible from the iDRAC.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC1134
Message Unable to export the Lifecycle log data, because the export file size larger than
25MB and cannot be processed locally.
Detailed
Description
Unable to export the Lifecycle log data, because the export file size larger than
25MB and cannot be processed locally.
Recommended
Response
Action
Export the Lifiecycle Log to a network file share. Using the RACADM command line
utility, run the lclog export command with --complete option and related network
file share parameters, and then retry the operation. For more information about the
--complete option, run the "racadm help lclog export" command at the command
line interface.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
1415