Reference Guide
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0760
Message Unable to perform physical disk(s) storage configuration operations for the
selected controller.
Detailed
Description
Unable to perform storage configuration operations on physical disk drive(s) as
there are no disk drive(s) available with Ready/RAID/NON-RAID state or the
selected controller is in HBA mode.
Recommended
Response
Action
Check the following: 1) If there are no physical disk drive(s) in either Ready state or
in RAID/NON-RAID state, insert additional disk drive(s). 2) If the Controller(s) are in
HBA mode, switch the controller(s) to RAID mode. To switch controller(s) to RAID
mode using the F2 System Setup utility, go to Device Settings > RAID Controller >
Controller Management > Advanced Controller Management > Switch to RAID
mode.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0761
Message Unable to retrieve system inventory.
Detailed
Description
The system inventory cannot be retrieved because another system inventory
operation may already be in progress or due to an internal issue whether or not
Collect System Inventory On Restart (CSIOR) is enabled or disabled.
Recommended
Response
Action
A system inventory operation may be in progress. Wait for the operation to
complete and retry the operation. If no other system inventory operation is in
progress, enable the Collect System Inventory On Restart (CSIOR) feature, reboot
the system, and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0762
Message Unable to perform a firmware update because a valid catalog file is not available on
the network share.
Detailed
Description
Unable to perform a firmware update because a valid catalog file is not available on
the network share.
1358