Reference Guide

Category System Health (ASR = Auto Sys Reset)
Severity Severity 1 (Critical)
Trap/EventID 2233
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
ASR0008
Message The watchdog timer interrupt was initiated.
Detailed
Description
The operating system or an application failed to communicate to the baseboard
management controller (BMC) within the timeout period. The BMC invoked a
system interrupt. (IPMI sensor type code 23h - offset 00h)
Recommended
Response
Action
Check the operating system, application, hardware, and system event log for
exception events.
Category System Health (ASR = Auto Sys Reset)
Severity Severity 1 (Critical)
Trap/EventID 2233
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
ASR0009
Message The system returned from a watchdog timer event.
135