Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
RAC0712
Message Server failed to power up due to zero power allocated.
Detailed
Description
Server failed to power up due to zero power allocated.
Recommended
Response
Action
Utilize the Chassis Management Controller web interface to check available power
and server power requirements. If sufficient power is available, allocate power
necessary and retry the operation.
Category Audit (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
RAC0713
Message Server failed to power up due to fabric mismatch.
Detailed
Description
Server failed to power up due to fabric mismatched.
Recommended
Response
Action
Ensure that the hardware comtibility between the IO Module (IOM) and the
Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct
component compatibility.
Category Audit (RAC = RAC Event)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC