Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
RAC0690
Message The iDRAC Service Module is not installed on the operating system of the server.
Detailed
Description
The iDRAC Service Module is not installed on the operating system of the server.
Recommended
Response
Action
Install the iDRAC Service Module and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0692
Message Unable to assign and un-assign physical disk drives as global hotspare(s), because
Lifecycle Controller is not enabled.
Detailed
Description
Unable to assign and un-assign physical disk drives as global hotspare(s), because
Lifecycle Controller is not enabled.
Recommended
Response
Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to
enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable,
and save the changes. Retry the operation after the server has restarted.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0693
Message Pending operations are created for the selected operations on the selected
physical disk drives.
1331