Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC0676
Message Unable to assign physical disk drives as global hotspare(s).
Detailed
Description
Unable to assign physical disk drives as global hotspare(s). This may be because
there are no disk drives available in a ready state or there are no virtual disks
present.
Recommended
Response
Action
Do one of the following and retry the operation: 1) If there are no disk drives
available in ready state, insert additional disk drives and make sure the drives are in
ready state. 2) If no virtual disks are present, click <create virtualdisk link> and
create at least one virtual disk. 3) If the physical disk drive(s) are in non-RAID mode,
convert them to RAID mode by pressing Ctrl+R while restarting the server, and
then select the required controller. Press F2 and select the Convert to RAID
capable option, and then complete the operation.
Category Storage (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0677
Message No physical disk drives in ready state, no virtual disks are created, and no PCIe SSD
drives are available to perform operations on.
Detailed
Description
No physical disk drives in ready state, virtual disks, or PCIe SSD drives are available
to perform operations on.
Recommended
Response
Action
Do one of the following: 1. If there are no disk drives available in ready state, insert
additional disk drives and make sure the drives are in ready state. 2. If no virtual
disks are present, click <create virtualdisk link> and create at least one virtual disk.
3. If PCIe SSD drives are inserted into the enclosure or attached to the backplane.
Category Storage (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0678
Message Unable to perform Prepare to Remove or Secure Erase operations on PCIe SSD disk
drives.
1325