Reference Guide

Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0660
Message Unable to access the specified file server location.
Detailed
Description
The file server cannot be accessed because of incorrect credentials.
Recommended
Response
Action
Check the file server credentials and retry the operation.
Category Audit (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0661
Message Storage configuration operation - #(operation) is pending on the selected
#{devicetype} : #{devicename}.
Detailed
Description
Various storage configuration operations can be performed on different devices
such as physical disks, virtual disks, controllers, or enclosures. The operations are
applied to the device by creating a configuration job on the associated controller.
Recommended
Response
Action
To complete the storage configuration operation, create a storage configuration
job with the necessary scheduling.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0662
Message The Clear Foreign Configuration operation will delete the foreign virtual disk
information from the controllers associated physical disk drives. Clearing will
remove metadata associated with the virtual disks, making the physical disk drives
available for creating new virtual disks. To remove foreign data, perform an
initialization operation.
Detailed
Description
Clear foreign configuration will delete the foreign virtual disk information from the
controllers associated physical disk drives. Clearing will remove metadata
associated with the virtual disks, making the physical disk drives available for
creating new virtual disks. To remove foreign data, perform an initialization
operation.