Reference Guide

Recommended
Response
Action
Make sure the integrated NICs are enabled from BIOS setup and support OS to
iDRAC Pass-Through, then retry the operation. To access BIOS setup, press F2
during system startup. For more information about OS to iDRAC Pass-Through, see
iDRAC7 Users Guide.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0608
Message The iDRAC will restart when the iDRAC firmware update is complete. All current
user sessions will be closed.
Detailed
Description
The message appears in Job Queue page when the iDRAC firmware update job
status is downloading. Communication to the iDRAC will be lost when the iDRAC
restarts to complete the firmware update.
Recommended
Response
Action
Reconnect iDRAC communications session after iDRAC is restarted. The iDRAC will
be ready for login once the restart is complete.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0609
Message The job arg1 has been successfully added to the job queue.
Arguments arg1 = import or export job ID
Detailed
Description
The import or export system configuration operation with the job ID indicated in
the message was successfully added to the Job Queue.
Recommended
Response
Action
No response action is required. The status of jobs can be viewed on the Job Queue
page.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC061
Message Unable to set the IPMI Watchdog because the OS Watchdog is already enabled..
1301