Reference Guide

PWR8686
Message The Chassis Management Controller (CMC) is unable to turn on the storage sleds
associated with server in slot arg1 because the iDRAC firmware version in the server
does not support the chassis storage module.
Arguments arg1 = slot number
Detailed
Description
The Chassis Management Controller (CMC) is unable to turn on the storage sled
controller identified in the message because iDRAC version installed on the server
is not compatible.
Recommended
Response
Action
Update the the iDRAC firmware identified in the message to the supported latest
available version and retry the operation. For information about the supported
firmware versions, refer to the Chassis Management Controller users Guide
available at the support site.
Category System Health (PWR = Power Usage)
Severity Severity 2 (Warning)
Trap/EventID 2274
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * *
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * * *
PWR8687
Message The Chassis Management Controller (CMC) is unable to turn on the storage sled
controller installed on server in slot arg1 because the server does not have a
Mezzanine card.
Arguments arg1 = server slot
Detailed
Description
The Chassis Management Controller (CMC) is unable to turn on the storage sled
controller installed on the server in the slot identified in the message because the
server does not have a Mezzanine card. A Mezzanine card position is identified with
the following numbers: For quarter-width server, the position number is 1. For half-
width server mezzanine C & B maps to position numbers 1 & 2 respectively. For
full-width server, Mezzanine C & B on the upper- or left part of the server maps to
position numbers 1 & 2 respectively. Mezzanine C & B on the lower- or right part of
the server maps to position numbers 3 & 4 respectively.
1222