Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔* ✔* ✔*
PWR8681
Message The arg1 firmware in the server slot arg2 does not support additional PCIe slots.
Arguments arg1 = iDRAC/BIOS, arg2 = slot number
Detailed
Description
The firmware identified in the message does not support the PCIe reassignment
operation.
Recommended
Response
Action
Update the firmware identified in the message to the supported latest available
version. See the latest iDRAC User Guide for information on the versions that
support the PCIe reassignment.
Category System Health (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 2273
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔* ✔*
PWR8682
Message Unable to turn on the storage sled controller arg1 in slot arg2 because the arg3
module is not functioning.
Arguments arg1 = controller number, arg2 = slot number, arg3 = module name
Detailed
Description
The Chassis Management Controller (CMC) is unable to turn on the storage sled
controller identified in the message. The Chassis storage sled controller is unable
to turn on due to a configuration or hardware issue.
Recommended
Response
Action
Remove the storage sled identified in the message, re-insert it and observe
whether the issue is resolved. If the issue persists, contact your service provider.
Category System Health (PWR = Power Usage)