Reference Guide

Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
PWR8670
Message Unable to turn on server arg1 because the required power arg2 AC Watts exceeds
the subsystem Connector Limit arg3 AC Watts for IO modules, Blowers and
Servers.
Arguments arg1 = slot ID, arg2 = power level, arg3 = power limit
Detailed
Description
The server identified in the message cannot be turned on if the Connector Limit for
the subsystems identified in the message is exceeded .
Recommended
Response
Action
Make sure the system operates within the subsystem Connector Limit for the
components specified. To review power budget information select Chassis
Overview -> Power -> Budget Status. Turn off unused components within the
subsystem to make power available for the server to turn on or turn off low priority
servers and try the operation again.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Trap/EventID 8418
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
1213