Reference Guide

AMP0310
Message Disk drive bay arg1 current is outside of range.
Arguments arg1 = name
Detailed
Description
Product documentation contains information on correct configuration. The failure
could also be caused by a faulty component or related cabling. System
performance may be degraded.
Recommended
Response
Action
Review system power policy, check system logs for power related failures, and
review system configuration changes.
Category System Health (AMP = Amperage)
Severity Severity 1 (Critical)
Trap/EventID 2177
LCD Message Disk drive bay <name> current is outside of range. Contact Support
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
AMP0311
Message Disk drive bay arg1 current is within range.
Arguments arg1 = name
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (AMP = Amperage)
Severity Severity 3 (Informational)
Trap/EventID 2179