Reference Guide

Arguments arg1 = component name, arg2 = slot number
Detailed
Description
CMC could not successfully turn on the component identified in the message,
because of insufficient power available.
Recommended
Response
Action
Make sure there is sufficient power available, and then retry the operation. To
increase available power, add more PSUs, use PSUs with higher voltage inputs or a
higher power rating, remove unused components from the Chassis, or change the
redundancy policy to Redundancy Alerting Only or Non-redundant.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Trap/EventID 8418
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
PWR8663
Message Unable to turn on the server arg1 because of an inconsistency between the I/O
module and mezzanine card.
Arguments arg1 = server number
Detailed
Description
The server identified in the message could not be successfully turned on because
of incompatibility between the I/O module and mezzanine card.
Recommended
Response
Action
Make sure that the I/O module and mezzanine card are compatible. For
information about compatibility of hardware components, see the Modular System
Chassis Hardware Manual.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
1209