Reference Guide
PWR8602
Message The multinode sled power button is enabled.
Detailed
Description
The power buttons for all multinode sleds in the chassis are enabled. The operation
to enable the power button is only applicable to the multinode sleds available, and
does not affect other servers in the chassis.
Recommended
Response
Action
To disable the chassis power button use the CMC RACADM command line
interface (CLI) or CMC Web interface. At the CLI, enter "racadm config -g
cfgChassisPower -o cfgChassisSledPowerButtonEnable 0". Using the Web
interface, click Server Overview > Power > Control. Select the "Disable power
button for all multinode sleds in the chassis" check box.
Category Configuration (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
PWR8654
Message Chassis Management Controller (CMC) is unable to send power allocation
information to the component arg1 - arg2 .
Arguments arg1 = component name, arg2 = component id
Detailed
Description
CMC could not successfully send the power allocation information to the
component identified in the message, because either iDRAC is stopped after the
power allocation was sent by CMC or the communication between CMC and
iDRAC has ended.
Recommended
Response
Action
Perform a Virtual Reseat operation of the component, and then retry the operation.
To virtually reseat a component, log in to the CMC Web interface, select Chassis
Overview > Troubleshooting > Reset Components > select the option
corresponding to the component, and then click Virtual Reseat.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
1207