Reference Guide
Detailed
Description
The Power Supply Unit (PSU) identified in the message is turned off because it is
not compatible with the other PSUs in the Chassis.
Recommended
Response
Action
Replace the PSU with an appropriate unit, and then retry the operation. For a list of
PSUs that are compatible, consult the system Owners Manual or contact your
service provider.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔* ✔*
PWR8601
Message The multinode sled power button is disabled.
Detailed
Description
The power buttons for all multinode sleds in the chassis are disabled. The
operation to disable the power button is only applicable to the multinode sleds
available, and does not affect other servers in the chassis.
Recommended
Response
Action
To enable the chassis power button use the CMC RACADM command line
interface (CLI) or CMC Web interface. At the CLI, enter "racadm config -g
cfgChassisPower -o cfgChassisSledPowerButtonEnable 1". Using the Web
interface, click Server Overview > Power > Control. Clear the Disable power button
for all multinode sleds in the chassis" check box.
Category Configuration (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*