Reference Guide

Detailed
Description
The Chassis Management Controller cannot turn on the server identified in the
message, because PSU redundancy is lost or PSUs are removed. Sufficient power is
not available for the operation.
Recommended
Response
Action
Make sure there is enough power supply to distribute power. Go to, the Chassis
Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field, view the available power. To add more power, insert more PSUs or
remove unused components from the chassis. When enough power is available,
retry the operation.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
PWR8597
Message The Power Supply Unit (PSU) arg1 is turned off because it is not supported by the
Chassis.
Arguments arg1 = PSU number
Detailed
Description
The identified Power Supply Unit (PSU) is turned off because it is not supported by
the Chassis.
Recommended
Response
Action
Replace the PSU identified in the message with an appropriate unit, and then retry
the operation. For a list of PSUs that are compatible, consult the system Owners
Manual or contact your service provider.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
PWR8598
Message The Power Supply Unit (PSU) arg1 is turned off because it is not compatible with
the other PSUs used in the Chassis.
Arguments arg1 = PSU number
1205