Reference Guide

Arguments arg1 = requested watts, arg2 = available watts
Detailed
Description
The available power is not sufficient to enable the Enhanced Cooling Mode feature.
Recommended
Response
Action
Make sure there is enough power supply to enable the Enhanced Cooling Mode
feature. Go to, the Chassis Overview > Power > Power Budget Status. In the Total
Input Power Available For Allocation field view the available power. To add more
power, insert more PSUs or remove unused components from the chassis.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
PWR8595
Message Chassis Management Controller is unable to turn on server arg1 due to insufficient
power for the arg2 .
Arguments arg1 = slot id, arg2 = chassis component name
Detailed
Description
The turn-on request for the server identified in the message did not succeed
because of insufficient power to the chassis component identified in the message.
Recommended
Response
Action
The Chassis Management Controller (CMC) will retry turning on the server and the
corresponding components associated to the server after a predefined interval. If
the issue persists, refer to the Managing and Monitoring Power section in the CMC
User Guide for more information on configuring power management settings.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8596
Message Chassis Management Controller is unable to turn on server- arg1 because PSU
redundancy is lost and the available power is insufficient.
Arguments arg1 = slot number
1204