Reference Guide
PWR8583
Message Chassis Management Controller is unable to turn on server- arg1 because
unacknowledged 110V PSUs are present.
Arguments arg1 = slot number
Detailed
Description
To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If
the feature is not enabled, the server turn-on operation will not be processed.
Recommended
Response
Action
On the Power Configuration page, in the Web UI, select the Allow 110VAC
Operation for power supplies and retry the operation. Using the RACADM utility,
run the following command, "racadm config -g cfgChassisPower -o
cfgChassisAllow110VACOperation 1".
Category Audit (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PWR8584
Message Chassis Management Controller is unable to turn on server- arg1 because the
power supply redundancy is lost and Performance Over Power Redundancy
feature is disabled and the power required is less than the available power.
Arguments arg1 = slot number
Detailed
Description
If power redundancy is lost and the server Performance Over Power Redundancy
feature is disabled, the server turn-on will not be allowed.
Recommended
Response
Action
To enable the server to be turned-on, on the Power Configuration page in the Web
UI, enable the server Performance Over Power Redundancy option . Using the
RACADM utility, run the following command "racadm config -g cfgChassisPower -
o cfgChassisPerformanceOverRedundancy 1". Then retry the operation.
Category Audit (PWR = Power Usage)
Severity Severity 3 (Informational)
1198