Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
PWR8580
Message Chassis Management Controller is unable to turn on server- arg1 because the
Chassis is not turned on.
Arguments arg1 = slot number
Detailed
Description
The power on request for the server identified in the message was not successful
because the Chassis is turned off.
Recommended
Response
Action
Turn on the Chassis, and then retry the operation. To turn on the Chassis using the
Chassis Management Controller Web UI, go to Chassis Overview > Power >
Control, select the Power On System option, and then click Apply.
Category Audit (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔*
CMC ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
PWR8581
Message Chassis Management Controller is unable to turn on server- arg1 because another
chassis power operation is in progress.
Arguments arg1 = slot number
Detailed
Description
A chassis power operation is currently in progress and the server identified in the
message could not be turned on.
1196