Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
PWR8566
Message Unable to turn off the Server arg1 before the Power Off timer expired.
Arguments arg1 = server number
Detailed
Description
Unable to turn off the Server before the Power Off timer has expired. This happens
if the Server did not show "power off" status change within 30 seconds after the
operation was initiated. This situation may also occur when iDRAC is rebooting.
Recommended
Response
Action
The Server may need more time to turn off. Wait for ten seconds and check the
power status. If the Server was not turned off, retry the operation. If the issue
persists, remove and reinsert the Server, wait for the iDRAC to complete startup,
and retry the operation.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
PWR8567
Message Unable to turn off Server arg1 on a power cycle action.
Arguments arg1 = server number
Detailed
Description
Unable to turn off the Server on a power cycle operation. This happens if the Server
did not show a "power off" status change within the expected time.
Recommended
Response
Action
The Server could have taken more time to turn off than expected. If the Server is
turned off, turn on to complete the power cycle. If the Server has not completed a
power cycle, retry the operation.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
1188