Reference Guide

Detailed
Description
The server identified in the message was not turned on because the available
power is less than the requested power.
Recommended
Response
Action
Utilize the Chassis Management Controller web interface to check the System
Input Max Power Capacity Power and server power requirements. If sufficient
power is available, retry the operation. Otherwise, increase the System Input Power
Cap value.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Trap/EventID 8418
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
PWR8565
Message Unable to turn off the Server arg1 due to iDRAC communication issue.
Arguments arg1 = server number
Detailed
Description
The Chassis Management Controller is unable to communicate with the iDRAC
service processor for the Server identified in the message and the Server could not
be turned off. This situation may occur when iDRAC is rebooting.
Recommended
Response
Action
Do the following: 1) Wait for a few minutes for the iDRAC service processor to
complete startup. 2) Retry the operation. 3) If the issue persists, reset the iDRAC
and wait a few minutes for the iDRAC startup to complete before retrying the
operation.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
1187