Reference Guide

Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8563
Message Unable to turn on Server arg1 due to I/O fabric inconsistency.
Arguments arg1 = server number
Detailed
Description
The Server identified in the message did not turn on due to a fabric mismatch
between the I/O Module and the Mezzanine card on the Server.
Recommended
Response
Action
Make sure that the hardware compatibility between the I/O Module (IOM) and the
Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct
component compatibility.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
PWR8564
Message Unable to turn on the Server arg1 because the power request exceeded the System
Input Power Cap.
Arguments arg1 = slot number
1186