Reference Guide
PWR8559
Message Power cycle initiated for I/O Module arg1 .
Arguments arg1 = iIOM slot name
Detailed
Description
Power cycle initiated for the I/O module in the slot identified in the message.
Recommended
Response
Action
No response action is required.
Category Audit (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
PWR8560
Message Unable to turn on I/O Module arg1 due to insufficient chassis power.
Arguments arg1 = IOM slot name
Detailed
Description
Unable to turn on the I/O Module identified in the message due to insufficient
chassis power.
Recommended
Response
Action
Utilize the Chassis Management Controller (CMC) web interface to check available
power and I/O Module power requirements. If sufficient power is available, restart
the CMC and retry the operation. If sufficient power is not available due to an
insufficient number of PSUs, add additional PSU(s) and reinsert the I/O Module.
Category Audit (PWR = Power Usage)
Severity Severity 1 (Critical)
Trap/EventID 8417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
1184