Reference Guide
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
PWR8552
Message Chassis Management Controller is unable to turn on arg1 - arg2 because of
insufficient power.
Arguments arg1 = component name, arg2 = component id
Detailed
Description
There is insufficient power for the component identified in the message to turn on.
Recommended
Response
Action
Make sure there is enough power supply to distribute power. Using the CMC Web
UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input
Power Available For Allocation field view the available power. To add more power,
insert more PSUs or remove unused components from the chassis. Contact your
service provider for information on the power required for the component
identified in the message.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Trap/EventID 8418
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
PWR8554
Message Chassis Management Controller is unable to send power allocation information to
arg1 - arg2 at priority arg3 .
1180