Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8527
Message Server slot power priorities changed - reallocating power.
Detailed
Description
Server slot power priorities were changed. Power to servers is being reallocated.
Recommended
Response
Action
No response action is required.
Category Audit (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8528
Message Unable to set Max Power Conservation Mode because the Server Based Power
Management mode is enabled.
Detailed
Description
The Max Power Conservation Mode can be enabled only when Server Based Power
Management Mode is disabled.
Recommended
Response
Action
The Max Power Conservation Mode can be changed when Server Based Power
Management mode is disabled. Using the CMC Web UI, navigate to the Chassis
Overview > Power > Configuration page, then uncheck the Enable Server Based
Power Management checkbox. Retry the operation.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
1167