Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PWR3001
Message Detected new peak power value. Peak value (in Watts): arg1 .
Arguments arg1 = peak value
Detailed
Description
The system has detected a new peak power value.
Recommended
Response
Action
Make sure that the power usage corresponds to the the current hardware
configuration and workload.
Category System Health (PWR = Power Usage)
Severity Severity 3 (Informational)
OMSA Event ID 5013
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
PWR8500
Message Chassis power state updated to arg1 from arg2 .
Arguments arg1 = new power state, arg2 = old power state
Detailed
Description
The chassis power state from the configuration database and the current state are
different. The current chassis power state will be updated in the configuration
database. This is to insure the chassis power state will be the same if the CMC is
rebooted or a CMC failover occurs. Note that the numerical value of the state is
intended for technical support use.
Recommended
Response
Action
No response action is required.
Category Audit (PWR = Power Usage)
1153