Reference Guide
Detailed
Description
The iDRAC controller cannot communicate with the power management firmware
due to an problem with the interface to the power management engine or with the
power management engine itself. The system may operate in a performance
degraded state.
Recommended
Response
Action
Check the Lifecycle Controller Log (LC Log) and make sure that there are no
subsequent log entries indicating that Communication with power management
firmware has been restored. If this log entry is not present then do one of the
following: 1) Disconnect system input power, wait one minute, reconnect system
input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest
revision.
Category System Health (PWR = Power Usage)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
PWR2403
Message iDRAC communication with power management firmware has been restored.
Detailed
Description
The iDRAC controller established communication to the power management
firmware. System performance will return to normal.
Recommended
Response
Action
No response action is required.
Category System Health (PWR = Power Usage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1151