Reference Guide

Detailed
Description
The Chassis Managment Controller (CMC) is configured in Max Power
Conservation Mode and is unable to grant power on permission to the server.
Recommended
Response
Action
Disable the Max Powe Conservation Mode on the chassis and retry the operation.
Using the Chassis Management Controller (CMC) web interface, select Chassis
Overview>Power>Configuration and then uncheck the Max Power Conservation
Mode field.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PWR2256
Message Unable to allocate power for servers to turn on because the Chassis Management
Controller (CMC) is initializing chassis infrastructure components.
Detailed
Description
The chassis infrastructure components are being initialized and are not ready to
grant power on permission to the servers.
Recommended
Response
Action
Wait until the chassis infrastructure has been initialized and then retry the
operation. To check that the infrastructure is initialized, using the RACADM
command line utility run the command "racadm getmodinfo" and check that the
"pwrstate" field is on for the chassis component.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
1145