Reference Guide

Category System Health (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PWR216
Message Unable to enable Extended Power Performance, because Redundancy Policy is set
to Grid Redundancy or No Redundancy.
Detailed
Description
Unable to enable Extended Power Performance, because redundancy policy is set
to Grid Redundancy or No Redundancy.
Recommended
Response
Action
Configure Redundancy Policy to Power Supply Redundancy and retry the
operation. Using the CMC Web GUI, click Power > Configuration. From the
Redundancy Policy drop-down menu, select Power Supply Redundancy.
Category System Health (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PWR218
Message Cannot enable the Extended Power Performance (EPP) feature because the Fresh
Air (FA) mode is enabled.
Detailed
Description
Cannot enable the Extended Power Performance (EPP) the feature because the
Fresh Air (FA) mode is enabled.
1132