Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU8518
Message Unable to access the PSU arg1 FRU data.
Arguments arg1 = slot number
Detailed
Description
The operation to read the FRU data from the PSU identified in the message did not
complete successfully due to internal communication errors.
Recommended
Response
Action
Retry the operation. If the condition persists, contact your service provider.
Category Audit (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 8329
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
PSU8519
Message Enhanced Dynamic Power Supply Engagement (DPSE) is not supported by the
current power supply configuration and is suspended.
Detailed
Description
The Dynamic Power Supply Engagement (DPSE) feature is suspended due to the
configuration or the type of PSU present. The feature is enabled, but suspended
until a supported PSU configuration is in place.
Recommended
Response
Action
Dynamic Power Supply Engagement (DPSE) is not supported by the current power
supply configuration. Verify the PSUs are supported. Replace the unsupported
PSUs.
Category Audit (PSU = Power Supply)
Severity Severity 2 (Warning)
1106