Reference Guide

Recommended
Response
Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health (PSU = Power Supply)
Severity Severity 2 (Warning)
OMSA Event ID 5351
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU1050
Message arg1 is switched ON.
Arguments arg1 = power supply name
Detailed
Description
The power supply identified in the message is switched ON.
Recommended
Response
Action
No response action is required.
Category Storage (PSU = Power Supply)
Severity Severity 3 (Informational)
OMSA Event ID 2323
OMSA Trap ID 100100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
1095