Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
PSU100
Message Power supply arg1 is offline.
Arguments arg1 = power supply unit
Detailed
Description
The power supply unit identified in the message is offline, because of the one of
the following reasons: 1) The power supply unit is not correctly seated. 2) The
power cable may not be connected properly or diconnected. 3) The power supply
unit has failed. 4) There is an input power failure.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health (PSU = Power Supply)
Severity Severity 2 (Warning)
OMSA Event ID 5303
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
PSU1000
Message Power supply cable has been removed from arg1 .
Arguments arg1 = PSU Sensor Name
Detailed
Description
The power supply unit is not receiving input AC power. The power cable may not
be connected properly or removed. This can happen if there is an AC failure or
problems with the power strip attached to the enclosure power supply.
Recommended
Response
Action
Reconnect the power cable to the power supply unit if it was disconnected.
Restore the input AC power supply. Make sure the power supply is restored to the
enclosure from the mains.
Category Storage (PSU = Power Supply)
1088