Reference Guide
Trap/EventID 2187
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
PSU0039
Message An under current fault detected on power supply arg1 .
Arguments arg1 = number
Detailed
Description
Insufficient amount of current to keep power supply operating at a normal levels.
Recommended
Response
Action
1) Remove and re-install the power supply input cord. 2) Check power distribution
or PSU input source for anomalies. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Under current fault detected on PSU <number>. Check PSU.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC ✔* ✔*
PSU0040
Message An output under voltage fault detected on power supply arg1 .
Arguments arg1 = number
1069