Reference Guide

Recommended
Response
Action
Review server product documentation for supported power supplies and power
supply configurations.
Category System Health (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Power supply <number> is incorrectly configured. Check PSU.
OMSA Event ID 5354
OMSA Trap ID h
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PSU0007
Message Power supply arg1 is operating at 110 volts, and could cause a circuit breaker fault.
Arguments arg1 = number
Detailed
Description
A power supply that is designed to operate at 220V, but is connected to a 110V
power source requires additional current for operation. The additional current may
trip circuit-breakers or cause other electrical issues with the input source.
Recommended
Response
Action
Check input power source and cabling. Use recommended input power. Review
the product documentation. If the issue persists, contact technical support. Refer
to the product documentation to choose a convenient contact method.
Category System Health (PSU = Power Supply)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1061