Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC ✔*
PSU0005
Message The power input for power supply arg1 is outside of the allowable range, but it is
attached to the system.
Arguments arg1 = number
Detailed
Description
The operating requirements for the power supply may be found in product
documentation or on the power supply itself.
Recommended
Response
Action
Verify the input power is within the operating requirements for the power supply.
Category System Health (PSU = Power Supply)
Severity Severity 2 (Warning)
Trap/EventID 2186
OMSA Event ID 5353
OMSA Trap ID 5353
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC ✔*
PSU0006
Message Power supply arg1 is incorrectly configured.
Arguments arg1 = number
Detailed
Description
The power supply identified in the message must be supported by the platform.
Generally, multiple power supplies in the server should have the same feature set
and power rating.
1060